Alpine Equipment Manuals

AutoMill HP Product Manual

Issue link: http://alpine.uberflip.com/i/577795

Contents of this Issue

Navigation

Page 6 of 167

7 AutoMill HP ™ P R O D U C T M A N U A L EN 1.2.3. Service Requirements Electrical • 440-496 VAC, 100 A, 3PH, 60 Hz • Y-configuration preferred (delta acceptable) • Phase Voltage Imbalance – 12 V • e (V t ) - ≤ 50Vsec @ ≤ 1 occurrence per half hour V t =V i x t Where: V t =Transient Voltage (Vsec) V i =Instantaneous Voltage (V) T =Time (sec) Air • Place coalescer immediately prior to machine to insure dry, oil-free air. • Machine has a factory installed filter with pressure regulator. ! CAUTION Introduction of oil to air system will damage seals on pneumatic system. NOTE 110 PSI is the minimum recommended pressure in the main air line. C M Y CM MY CY CMY K AutoMillHP-footprint.pdf 1 5/12/15 10:44 AM Footprint