Alpine Equipment Manuals

AutoMill HP Product Manual

Issue link: http://alpine.uberflip.com/i/577795

Contents of this Issue

Navigation

Page 22 of 167

23 AutoMill HP ™ P R O D U C T M A N U A L EN Step 20. Perform Steps 11 to 19 but select Head 3 Angle on the Calibration Menu. Step 21. Re-cut the same board used in Steps 1 to 10, but adjust the length 3 inches shorter. NOTE Repeat steps 1 to 21 until the angle cuts are correct. 4.3.2. Head 1,4 Angle Calibration Step 1. Turn the Key Switch to SETUP (Section 2.3). Step 2. Select SEMI on the Main Menu (Figure 5). Step 3. On the Board Select Menu (Figure 14) setup a two-cut chord as shown in Figure 36. Figure 36 • Set Angle 1 to 90 • Set Angle 2 to 45 • Set Angle 3 to 90 • Set Angle 4 to 45 • Set Height 1 to 0-3-8 • Set Height 2 to 0-0-4 • Set Height 3 to 0-3-4 • Set OA Len to 10-0-0 NOTE The remaining length values will calculate automatically. Step 4. Click SETUP on the Board Select Menu (Figure 14). Step 5. Click SETUP on the Run Menu. Step 6. Wait for the saw to move into position and turn the Key Switch to RUN. Step 7. Click AutoStart on the Run Menu. Step 4. Click SETUP on the Board Select Menu (Figure 14). Step 5. Click SETUP on the Run Menu. Step 6. Wait for the saw to move into position and turn the Key Switch to RUN. Step 7. Click AutoStart on the Run Menu. Step 8. Feed one board through the saw. Step 9. Using a carpenter's square, measure each of the two angles checking for a 12/12 pitch (Appendix E). NOTE Every 1/8 inch shown on the carpenter's is equal to .25 degrees. Step 10. Make note the measurements for each side of the cut piece as each angle will be calibrated separately. If the pitch of the angle on each end of the board is not 12/12 the saw is out of calibration. Continue with the next set of steps to adjust the calibration. NOTE Only follow the upcoming steps if the board did not measure correctly after performing Step 1 to Step 10 above. Step 11. Click Calibration on the Main Menu Toolbar (Figure 5). Step 12. Click Head 2 Angle on the Calibration Menu (Figure 30). Step 13. Click Move To on the Axis Calibration Screen (Figure 33). The Command Value Screen will open. Step 14. Using the Blade Angle Calibration Table in Appendix A, make a note of the new calibration value. Step 15. Click the command value box and enter the new calibration value (from the Blade Angle Calibration Table) using the keypad. Step 16. Click ENTER. Step 17. Click START MOVE on the Command Value Screen (Figure 34). Step 18. Click DONE on the Command Value Screen (Figure 34). Step 19. Click Calibrate on the Axis Calibration Screen (Figure 33).

Articles in this issue

view archives of Alpine Equipment Manuals - AutoMill HP Product Manual