Alpine Equipment Manuals

AutoSet Plus Product Manual

Issue link: http://alpine.uberflip.com/i/935082

Contents of this Issue

Navigation

Page 5 of 155

6 AutoSet Plus P R O D U C T M A N U A L EN 1.2. General Specifications 1.2.1. Equipment Specifications (Figure 1) Gantry Roller Face Width 14 ft. 7 in. Gantry Overall Width 18 ft. 7 in. Gantry Travel Speed 140 in./min. Table Length (Per table) 7 ft. 1 in. Table Width (Between Rails) 14 ft. 3 in. Maximum distance between top and bottom automated pucks 12ft. 6 in. Truss Jigging Setups/Groups 1 to 4 groups per system Air Requirement 2 CFM per liftout at 100 PSI (when activated, not a constant draw) Operating Temperature 32° to 104° F 1.2.2. Electrical Specifications Equipment Voltage Phase Amps Conveyor 110 Single 30 220 15 Gantry 208 (Transformer) Three 25 230 (Transformer) 22 480 (Standard) 11 AutoSet Plus Amperage Requirements 30 Amp per Gantry 20 Amp for the Controller Box 20 Amp per 16 Automated Axis NOTE Customer must provide transformer if other than 480 V-3PH. 1.2.3. AutoSet Plus spacing options Option 1: (Figure 1) 4 Automated axis per table, and 4 manual axis per table • O.C. spacing between two automated axis is 1ft. 9-1/4in. • Each manual axis is centered between two automated axis. Figure 1

Articles in this issue

view archives of Alpine Equipment Manuals - AutoSet Plus Product Manual