7 RollerPress P R O D U C T M A N U A L EN Figure 1 RollerPress Footprint Standard Voltage Phase FLA (Amp) 230 Three 45 460 Three 20 NOTE It is recommended to have a 90 amp Instantaneous-trip circuit breaker with the 230 volt option, and a 50 amp Instantaneous-trip circuit breaker with the 460 volt option. Optional Voltage Phase FLA (Amp) 208 Three 45 600 Three 15 NOTE The 208 volt and 600 volt options require a 30 KVA transformer. 1.2.4. Electrical Specifications ! CAUTION A qualified electrician is required to ensure that the following service specifications are properly met.