Alpine

Structural Connectors Catalog 2015-2016

Issue link: http://alpine.uberflip.com/i/586848

Contents of this Issue

Navigation

Page 33 of 129

34 alpineitw.com (800) 521-9790 For Product Substitutions … the ONLY APPROVED EQUAL ™ Spruce-Pine-Fir (0.42 Specific Gravity) PRODUCT CODE Gauge Hanger Dimension Minimum Header Common Nail Type Fasteners 5 Allowable Load (lbs) Clear Seat Width, W (in.) Overall Height, H (in.) Overall Depth, D (in.) Breadth (in.) Depth (in.) Joist at 90 Degrees Joist at 45 Degrees Header Downward Upward Size Quantity Size Quantity Size Quantity In Face Quantity In Top Load Duration Factor Load Duration Factor 1.00 1.15 1.25 1.60 1.00 1.15 1.25 1.60 Top Mount Installation 4 STH29 18 1 5 ⁄8 8 25 ⁄32 2 5 ⁄16 3 5 1 ⁄2 na 0 0.148"x3" 4 0.148"x3" 4 4 2020 2120 2185 2420 665 765 830 1005 STH213 18 1 5 ⁄8 12 25 ⁄32 1 15 ⁄16 1 1 ⁄2 11 1 ⁄4 0.148"x1.5" 4 na 0 0.148"x3" 2 4 1515 1575 1605 1675 0 0 0 0 STH218 18 1 5 ⁄8 17 5 ⁄32 1 15 ⁄16 1 1 ⁄2 11 1 ⁄4 0.148"x1.5" 4 na 0 0.148"x3" 2 4 1515 1575 1605 1675 0 0 0 0 STH29-2 18 3 1 ⁄8 8 25 ⁄32 2 5 ⁄16 3 5 1 ⁄2 na 0 0.148"x3" 4 0.148"x3" 4 4 2705 2705 2705 2705 665 765 830 1005 STH218-2 16 3 1 ⁄4 16 1 ⁄16 1 31 ⁄32 3 11 1 ⁄4 0.148"x3" 6 na 0 0.162" x 3.5" 4 4 2840 2930 2990 3205 0 0 0 0 STH222-2 16 3 1 ⁄4 22 1 ⁄16 1 31 ⁄32 3 11 1 ⁄4 0.148"x3" 6 na 0 0.162" x 3.5" 4 4 2840 2930 2990 3205 0 0 0 0 STH413 18 3 5 ⁄8 12 25 ⁄32 1 15 ⁄16 1 1 ⁄2 11 1 ⁄4 0.148"x3" 4 na 0 0.148"x3" 2 4 1555 1585 1605 1675 0 0 0 0 STH418 16 3 5 ⁄8 16 1 ⁄16 1 31 ⁄32 3 11 1 ⁄4 0.148"x3" 6 na 0 0.162" x 3.5" 4 4 3190 3265 3280 3280 0 0 0 0 STH422 16 3 5 ⁄8 22 1 ⁄16 1 31 ⁄32 3 11 1 ⁄4 0.148"x3" 6 na 0 0.162" x 3.5" 4 4 3190 3265 3280 3280 0 0 0 0 STH426 16 3 5 ⁄8 26 1 ⁄16 1 31 ⁄32 3 11 1 ⁄4 0.148"x3" 6 na 0 0.162" x 3.5" 4 4 3200 3275 3280 3280 0 0 0 0 STH422-2 & STH422-2R 16 7 1 ⁄4 22 9 ⁄16 2 11 ⁄32 3 11 1 ⁄4 0.162"x3.5" 6 na 0 0.162"x3.5" 4 4 3430 3430 3430 3430 0 0 0 0 STH426-2 & STH426-2R 16 7 1 ⁄4 26 1 ⁄16 2 11 ⁄32 3 11 1 ⁄4 0.162"x3.5" 6 na 0 0.162"x3.5" 4 4 3430 3430 3430 3430 0 0 0 0 STHI1.81/22 16 1 13 ⁄16 21 13 ⁄16 1 31 ⁄32 3 11 1 ⁄4 0.148"x1.5" 2 na 0 0.148"x3" 2 4 1505 1535 1555 1625 0 0 0 0 STHI222 16 1 9 ⁄16 21 15 ⁄16 1 31 ⁄32 3 11 1 ⁄4 0.148"x1.5" 2 na 0 0.148"x3" 2 4 1320 1350 1370 1440 0 0 0 0 STHI322 16 2 9 ⁄16 21 7 ⁄16 1 31 ⁄32 3 11 1 ⁄4 0.148"x1.5" 2 na 0 0.148"x3" 2 4 1840 1840 1840 1840 0 0 0 0 STHI422 16 3 9 ⁄16 20 15 ⁄16 1 31 ⁄32 3 11 1 ⁄4 0.148"x1.5" 2 na 0 0.148"x3" 2 4 1840 1840 1840 1840 0 0 0 0 Face Mount Installation 3 STH29 18 1 5 ⁄8 8 25 ⁄32 2 5 ⁄16 3 9 1 ⁄4 na 0 0.148"x3" 4 0.148"x3" 16 0 2010 2120 2185 2400 665 765 830 1005 STH213 18 1 5 ⁄8 12 25 ⁄32 1 15 ⁄16 3 13 1 ⁄4 na 0 0.148"x3" 4 0.148"x3" 14 0 1780 1880 1945 2180 665 765 830 1065 STH218 18 1 5 ⁄8 17 5 ⁄32 1 15 ⁄16 3 13 1 ⁄4 na 0 0.148"x3" 4 0.148"x3" 14 0 1780 1880 1945 2180 665 765 830 1065 STH29-2 18 3 1 ⁄8 8 25 ⁄32 2 5 ⁄16 3 9 1 ⁄4 na 0 0.148"x3" 4 0.148"x3" 16 0 2010 2310 2400 2400 665 765 830 1005 STH218-2 16 3 1 ⁄4 16 1 ⁄16 1 31 ⁄32 1 1 ⁄2 16 1 ⁄2 na 0 0.162" x 3.5" 6 0.162" x 3.5" 22 0 3365 3605 3725 3920 1195 1375 1495 1915 STH413 18 3 5 ⁄8 12 25 ⁄32 1 15 ⁄16 3 13 1 ⁄4 na 0 0.148"x3" 4 0.148"x3" 14 0 1795 2065 2245 2465 665 765 830 1065 STH418 16 3 5 ⁄8 16 1 ⁄16 1 31 ⁄32 1 1 ⁄2 16 1 ⁄2 na 0 0.162" x 3.5" 6 0.162" x 3.5" 22 0 3365 3870 3920 3920 1195 1375 1495 1915 STH STHI ADJUSTABLE STRAP HANGERS Design Features… Superior performance and easy installation. The hanger's long straps can be field formed to the required height of the carried member. Face mount nailing options available. Designed and developed for Component Manufacturers to have a wide range of use including: • Ceiling hanger • Face mount hanger • Top flange hanger • Top flange over-the-back hanger All products carry IAPMO and FBC engineering approvals. Reverse flange options available on some products. Please specify bucket width at time of order. Material… 18 ga. and 16 ga. galvanized steel. Installation… • Use all specified nails indicated in the table. Verify that the header dimensions will accommodate the specified nails. • When less than the maximum number of nails are used, allowable load must be reduced for each nail eliminated. • See General Notes for more information. STH29 W Clear inside D H Face Installation Top Installation 2 1/4" min. STH218 W Clear Inside H D Face Installation Top Installation 2" min. STH422-2R W Clear inside D H Installation 1 2" min. Installation 2 2" min. STHI222 W Clear Inside H D Top Installation 2 1/2" min.

Articles in this issue

Links on this page

view archives of Alpine - Structural Connectors Catalog 2015-2016