Alpine

Structural Connectors Catalog 2015-2016

Issue link: http://alpine.uberflip.com/i/915756

Contents of this Issue

Navigation

Page 98 of 129

99 (800) 521-9790 alpineitw.com For Product Substitutions … the ONLY APPROVED EQUAL ™ PRODUCT CODE REF NO MIN STEM WALL (INCH) STRAP LENGTH L E (INCH) NAIL SCHEDULE DESIGN LOAD (LBS) MAX (1.33) EDGE DISTANCE STD MODEL RIM JOIST MODEL 1 ⁄2" 1 1 ⁄2" L E 1 ⁄2" 1 1 ⁄2" L E 1 ⁄2" 1 1 ⁄2" L E 2000 PSI CONCRETE 2500 PSI CONCRETE 3000 PSI CONCRETE LSSAD8 / LSSAD8RJ LSTHD8 / LSTHD8RJ 6 21 5 ⁄8 35 1 ⁄8 8 24-16d Sinker 1945 1945 1945 1945 1945 2430 2040 2190 2920 SSAD8 / SSAD8RJ STHD8 / STHD8RJ 6 21 5 ⁄8 35 1 ⁄8 8 24-16d Sinker 1805 2085 2780 2255 2605 3475 2710 3125 4170 SSAD10 / SSAD10RJ STHD10 / STHD10RJ 6 23 1 ⁄8 36 5 ⁄8 10 28-16d Sinker 2300 2525 3285 2875 3160 4105 3450 3790 4925 SSAD14 / SSAD14RJ STHD14 / STHD14RJ 6 31 5 ⁄8 39 5 ⁄8 14 38-16d Sinker 4075 4365 5820 5095 5455 5820 5820 5820 5820 LSSAD8 / LSSAD8RJ LSTHD8 / LSTHD8RJ 8 21 5 ⁄8 35 5 ⁄8 8 24-16d Sinker 2000 2000 2000 2500 2500 2500 3000 3000 3000 SSAD8 / SSAD8RJ STHD8 / STHD8RJ 8 21 5 ⁄8 35 1 ⁄8 8 24-16d Sinker 2605 2805 4005 3255 3505 5005 3905 4100 5820 SSAD10 / SSAD10RJ STHD10 / STHD10RJ 8 23 1 ⁄8 36 5 ⁄8 10 28-16d Sinker 3040 3270 4675 3800 3925 5820 4560 4710 5820 SSAD14 / SSAD14RJ STHD14 / STHD14RJ 8 31 5 ⁄8 39 5 ⁄8 14 38-16d Sinker 4255 4580 5820 5320 5725 5820 5800 5820 5820 SSAD14RJ uses 30-16d sinkers max. Allowable load @ L e = 5010 @ 1.33. L e = Length Embedment For Product Substitutions … the ONLY APPROVED EQUAL ™ PRODUCT CODE REF NO MATERIAL DIMENSIONS (INCHES) MIN STEM WALL (INCH) Le (INCH) NAIL SCHEDULE DESIGN LOAD (LBS) MAX (1.33) 2000 PSI 2500 PSI W L END DISTANCE 1 ⁄2" 8" 1 ⁄2" 8" SINGLE POUR SA2545 PAHD42 12 ga gal 2 25 3 ⁄8 6 6 1 ⁄2 12-16d 1160 2320 1450 2320 8 18-16d 1160 3350 1450 3350 HSA3522 HPAHD22 10 ga gal 2 1 ⁄16 35 6 10 16-16d 1405 3350 1535 3350 8 24-16d 2110 4865 2300 5030 DOUBLE POUR SA2545 PAHD42 12 ga gal 2 25 3 ⁄8 6 6 1 ⁄2 12-16d 1160 2320 1450 2320 8 12-16d 1160 2320 1450 2320 HSA3522 HPAHD22 10 ga gal 2 1 ⁄16 35 6 10 16-16d 1405 3350 1755 3350 8 19-16d 2010 3985 2515 3985 HSA3522-2P HPAHD22-2P 10 ga gal 2 1 ⁄16 39 6 14 16-16d 2460 3350 2460 3350 8 24-16d 2460 4865 2460 5030 HSA SSAD SA SA2545 HSA3522 or HSA3522-2P Installation to Forms SPALLING LOAD REDUCTION Spalling may occur when strap anchors are bent to a horizontal position and then straightened for installation to framing. This practice may require an adjustment to allowable loads and applies to both single and double pour applications. Corner SSAD Installation on 3-2x studs (for 2 pour, see footnote 4). SSAD Edge Installation SSAD14 Two Pour Installation SSAD14RJ Rim Joist Application

Articles in this issue

Links on this page

view archives of Alpine - Structural Connectors Catalog 2015-2016