A. Check this box to indicate that the
girder is carrying a #1 hip truss.
B. Type of #1 Hip controls how the
concentrated load is calculated. It
is important to select the proper
type.
C. Location where the #1 hip
connects to the girder as
measured from the end of the
girder.
D. Indicates which end of the girder
to locate the load from the #1 hip.
E. Once all fields are set properly,
select the OK button to close the dialog box.
6. Select the Apply button and then the Done button to apply the load to the girder.
Applied Loads:
1. Bottom chord triangulated load, located at left end of truss, is the load generated from
the supported end jacks
2. 4371# concentrated load represents the load placed on the girder from the #1 hip
girder.
3. 928.8 PLF bottom chord load represents the load placed on the girder from the 32'
common trusses.