Issue link: http://alpine.uberflip.com/i/221331
LS For Product Substitutions . . . the ONLY APPROVED EQUAL™ PRODUCT CODE DIMENSIONS (INCHES) JOIST SIZE WIDTH NAIL SCHEDULE HEIGHT HEADER DESIGN LOAD/ SLOPE ONLY JOIST NORMAL LBS UPLIFT LBS MAXIMUM LBS LS26 2X6 1⁹⁄₁₆ 5 6-10d 7-10d x 1¹⁄₂ 670 835 835 LS28 2X8 1⁹⁄₁₆ 6³⁄₄ 8-10d 9-10d x 1¹⁄₂ 895 1005 1005 LS210 2 X 10 1⁹⁄₁₆ 8¹⁄₂ 10-10d 11-10d x 1¹⁄₂ 1120 1400 1390 LS210 For Product Substitutions . . . the ONLY APPROVED EQUAL™ PRODUCT CODE REF NO JOIST SIZE MATERIAL DIMENSIONS (INCHES) WIDTH HEIGHT "A" FLANGE NAIL SCHEDULE HEADER JOIST LSS DESIGN LOAD (LBS) SLOPE ONLY NORMAL SKEW ONLY MAXIMUM NORMAL MAXIMUM UPLIFT LBS LSS26 LSU26 18 1¹⁄x 1⁹⁄₁₆ 4⁷⁄₈ 1>⁄₁₆ 6-10d 5-10d x 1¹⁄₂ 670 835 670 840 635 LSS28 LSSU28 18 1¹⁄x 1⁹⁄₁₆ 7¹⁄₈ 1>⁄₁₆ 10-10d 5-10d x 1¹⁄₂ 1005 1005 985 985 635 LSS210 LSSU210 18 1¹⁄x 1⁹⁄₁₆ 8¹⁄₂ 1>⁄₁₆ 10-10d 9-10d x 1¹⁄₂ 1120 1400 1120 1390 1140 LSS25 LSSUI25 18 1³⁄₄ 1¹³⁄₁₆ 8¹⁄₂ 1>⁄₁₆ 10-10d 9-10d x 1¹⁄₂ 1120 1400 1120 1390 1140 LSS2.06 LSSUI2.06 18 2 2Z⁄₁₆ 8¹⁄₂ 1C⁄v 10-10d 7-10d x 1¹⁄₂ 1110 1390 995 1205 730 LSS2.1 LSSU2.1 18 2¹⁄₁₆ 2¹⁄₈ 8¹⁄₂ 1C⁄v 10-10d 7-10d x 1¹⁄₂ 1110 1390 995 1205 730 LSS35 LSSIU35 18 2B⁄₁₆ 2³⁄₈ 8Z⁄₂ 1B⁄, 10-10d 7-10d x 1¹⁄₂ 1110 1390 995 1205 730 LSS310 LSSUH310 16 2¹⁄x 2⁹⁄₁₆ 8¹⁄₂ 3Z⁄, 18-16d 12-10d x 1¹⁄₂ 2295 2295 1600 1600 1150 LSS210-2 LSSU210-2 16 3 3¹⁄₈ 8¹⁄₂ 2M⁄, 18-16d 12-10d x 1¹⁄₂ 2430 3035 1625 1625 1150 LSS410 LSSU410 16 3¹⁄x 3⁹⁄₁₆ 8¹⁄₂ 2B⁄, 18-16d 12-10d x 1¹⁄₂ 2430 3035 1625 1625 1150 LSS4.12 LSSU4.12 14 4 4¹⁄₈ 9 2Z⁄v 24-16d 16-10d x 1¹⁄₂ 3215 4020 2300 2300 1150 LSS4.28 LSSU4.28 14 4¹⁄, 4¹⁄v 9 2C⁄, 24-16d 16-10d x 1¹⁄₂ 3215 4020 2300 2300 1150 LSS3510-2 LSSU3510-2 14 4C⁄v 4C⁄v 8⁷⁄₈ 3B⁄, 24-16d 16-10d x 1¹⁄₂ 3215 4030 2300 2300 1150 LSS5.12 14 5 5¹⁄₈ 9 2Z⁄v 24-16d 16-10d x 1¹⁄₂ 3215 4030 2300 2300 1150 LSSU5.12 LSS28 Installation Sequence Step 2 Skew flange to form acute angle. The other flange should then be bent back. Form hanger to fit your skewed angle. Step 1 Nail hanger to joist. Install the seat nail first. Step 3 Attach hanger to the header. Nail the acute angle side first. Nails must be installed at an angle. LSS5.12 Hanger Shown Skewed Right For Product Substitutions . . . the ONLY APPROVED EQUAL™ PRODUCT CODE DIMENSIONS (INCHES) W L REF NO NAIL SCHEDULE PLATE RAFTER DESIGN LOAD NORMAL LBS MAX LBS UPLIFT LBS SSC2 VPA2 1⁹⁄₁₆ 3¹⁄₂ 12-10d 4-10d x 1¹⁄₂ 1430 1790 SSC25 VPAI25 1¹³⁄₁₆ 3¹⁄₂ 12-10d 4-10d x 1¹⁄₂ 1430 1790 250 SSC35 VPAI35 2³⁄₈ 4¹⁄₂ 12-10d 4-10d x 1¹⁄₂ 1430 1790 250 SSC3 VPA3 2⁹⁄₁₆ 4¹⁄₂ 12-10d 4-10d x 1¹⁄₂ 1430 1790 250 SSC4 VPA4 3⁹⁄₁₆ 5¹⁄₂ 12-10d 4-10d x 1¹⁄₂ 1430 1790 SSC 250 250 Installation Sequence "B" Flange 10d x 1¹⁄₂" Common Required Pitch 10d Common 10d Common Step 1 Nail top nails to plate first. Second, Install nails to top plate (outside wall) at a slight angle to prevent splitting. Step 2 Adjust joist rafter with a hammer to seat "B" flange to the right pitch. Step 3 Nail "B" Flange nails in nail holes, straight down to lock the required pitch. Step 4 Use 10d x 1¹⁄₂ nails for the joist rafter (4) to prevent splitting. Nail at slight angle. SSC2 11 "A" Flange