Issue link: http://alpine.uberflip.com/i/148376
RELATED DESIGN INFORMATION SPACEJOIST TE™ FIRE-RATED ASSEMBLIES TEST RESULT SUMMARY FLOOR/CEILING ASSEMBLY; FINISH RATING - 22 MINUTES STC 50 WITH INSULATION AND RESILIENT CHANNELS STC 55 WITH LIGHTWEIGHT CONCRETE DESIGN NO. TSC/FCA 60-01 WITH SPACEJOIST METAL WEB, ASSEMBLY RATING: 60 MINUTES - UNRESTRAINED SPACEJOIST TE™ FIELD SOUND TRANSMISSION TEST— GENERAL NOTES TEST F-IIC Def. (db) Carpet/padding with 3/4" gypcrete 70 15 Vinyl flooring with 3/4" gypcrete 51 27 3/8'' laminate wood flooring with 3/4" gypcrete 54 30 Ceramic tile / insulayment with 3/4" gypcrete 52 TEST RESULT SUMMARY 28 PROJECT NUMBER 3018 02 50879 STORK® Twin City Testing Corp, 622 Cromwell Avenue, St. Paul, Minnesota 55114-1776 The test results contained in this report pertain only to the actual assemblies tested and not necessarily to all similar constructions. Please call SpaceJoist TE Engineering Dept. for complete documentation. FIELD SOUND TRANSMISSION CLASS (F-STC) - ASTM E366-97 FIELD IMPACT INSULATION CLASS (F-IIC) - ASTM E1007-97 SPACEJOIST TE™ FIRE-RATED ASSEMBLIES AND SUMMARY OF SOUND RATINGS FIRE RATING CEILING RESILIENT CHANNEL INSULATION *(3) STC RATING STC W/LIGHT WT. CONCRETE TSC / FCA 60-01 60 minutes 1 LAYER 5/8" TYPE C Yes *(4) 50 55 TSC / FCA 60-03 60 minutes SUSPENDED *(1) N/A NO RATING NO RATING TSC / FCA 60-09 60 minutes 2 LAYERS 1/2" TYPE X *(5) NO 50 55 TSC / FCA 90-01 90 minutes 2 LAYERS 5/8" TYPE X *(5) *(4) 52 57 QUALTIM 120 minutes 3 LAYERS 5/8" TYPE X Yes NO 53 60 *ASSEMBLY *(1) FIRE-RATED CEILING SYSTEM *(4) REQUIRED FOR SOUND RATINGS ONLY *(3) 1 1/2'' "MINERAL WOOL BATTS" *(5) RESILIENT CHANNEL REQUIRED FOR SOUND RATINGS ONLY FOR COMPLETE DETAILS 16 Details of each assembly can be found at Intertek Testing Services Directory www.etlsemko.com/ProdDir/index.htm Warnock Hersey Listed Products Directory of Listed Products Research Search Name: Truswal Or contact SpaceJoist TE Engineering Department at 800-521-9790