26 FloorMaster P R O D U C T M A N U A L EN 6.8. Safety Scanner Troubleshooting ! WARNING Electricity can kill, use high caution when reading the safety scanner error code. Prior to performing any work on the FloorMaster, verify that all power to the machine has been turned off following OSHA-approved lockout/tagout procedures (OSHA REGULATION 29 CFR 1910.147). ! WARNING For electrical problems, a qualified electrician needs to be contacted to identify the source of the problem and correct it. Failure to follow these precautions could result in a serious injury or fatality. E R R O R C O D E S P O S S I B L E C A U S E S P O S S I B L E S O L U T I O N S 002A Total amount of current on each output exceeds 1A maximum Check the wiring between each output and the load, and whether the load is broken. Check if the total amount of current is less than 1A. Please call licensed electrician for service 0010 The OSSD is short circuited or wired wrong Check the wiring for the OSSD against the FloorMaster wiring schematic (See Appendix B). Please call licensed electrician for service The scanner experienced a surge in voltage due to an inductive load Use a load with a surge absorber function, or apply surge protection to the load. Please call licensed electrician for service The scanner is being affected by an EMC environment Check the surrounding wiring and EMC environment. Please call licensed electrician for service The scanner display unit is broken Replace the display unit (Section 6.9) 0011 The OSSD is short-circuited or wired wrong Check the wiring for the OSSD against the FloorMaster wiring schematic (See Appendix B). Please call licensed electrician for service The scanner experienced a surge in voltage due to an inductive load Use a load with a surge absorber function, or apply surge protection to the load. Please call licensed electrician for service The scanner is being affected by an EMC environmen Check the surrounding wiring and EMC environment. Please call licensed electrician for service The scanner display unit is broken. Replace the display unit (see Section 6.9) 0014 Overcurrent occurs on OSSD 1 Check the wiring between OSSD 1 and the load, and whether the load is broken or not. Refer the the FloorMaster wiring schematic (See Appendix B). Please call licensed electrician for service 0015 Overcurrent occurs on OSSD 2 Check the wiring between OSSD 2 and the load, and whether the load is broken or not. Refer the the FloorMaster wiring schematic (See Appendix B ). Please call licensed electrician for service 0024 The connection cable is not correctly connected or the wires are damaged Check the cable connection. Please call licensed electrician for service The connected cable is being affected by an EMC environment Check the wiring and the surrounding EMC environment. Please call licensed electrician for service The power voltage is temporarily or continuously failing Replace the power source, increase the power capacity, or prepare a dedicated power source. Please call licensed electrician for service

Articles in this issue

view archives of Alpine Equipment Manuals - FloorMaster Product Manual