23 AutoSet C4 ™ P R O D U C T M A N U A L EN C O N D I T I O N C A U S E C H E C K C O R R E C T I O N 7.6 Truss liftouts and receivers not operating (single) No air pressure Air-line connection into manifold. Re-connect air line to manifold. Defective solenoid valve Check operation of solenoid valve manually. Repair/replace solenoid valve if it is inoperable. No signal getting to solenoid coils Check for broken/damaged wires. Call a qualied electrician to diagnose electrical issues with the solenoid coils. No signal to/from relay. Loose connections. Defective air cylinder Blow by from cylinder seal. Repair/replace defective air cylinder. Flow control shut o or defective Air ow through the ow valve adjustment screw closed. Adjust ow control valve. Inactive in program Not highlighted on computer screen. Activate in computer program. Defective relay Red LED illuminates for active relay. Call a qualied electrician to replace the relay. 7.7 Pucks not moving (full group/table) Breaker for pucks in the main distribution panel tripped Shorts, Broken/damaged wiring. Call qualied electrician to check for shorts and wiring issues. E-Stop pressed Check E-Stop on HMI. Reset E-Stop. No communication to section of tables CAT5 communication cable jumper from table to table. Contact Alpine Technical Support. Contactor in table electrical cabinet not pulled in Loose wires, defective contactor. Call qualied electrician to replace the contactor. Motor failure Call Alpine Technical Support. Replace defective motor. Power cable failure Call Alpine Technical Support. Replace defective power cable. 7.8 Pucks not moving (Individual) Motor failure Call Alpine Technical Support. Call qualied electrician to install the replacement power cable. Feedback cable failure Call Alpine Technical Support. Replace feedback cable. Call qualied electrician for electrical repairs. Drive failure Call Alpine Technical Support. Replace faulty drive. Drive programs corrupt Call Alpine Technical Support Call Alpine Technical Support. Puck is jammed Physical debris jamming puck. Clear debris and/or unjam puck. Puck disabled in program Maintenance panel. Highlight axis and click on enable. Motor to rod coupling loose Check motor to rod coupling. Replace the motor coupling. Axis faulted out Maintenance panel (axis has red fault light on). Highlight axis in maintenance panel, disable then enable the axis to clear the fault.

Articles in this issue

view archives of Alpine Equipment Manuals - AutoSet C4 Product Manual