5
AutoSet C4
™
P R O D U C T M A N U A L
EN
1.2.2. Electrical Specications
Equipment Voltage Phase Amps
Conveyor
110
Single
30
220 15
Gantry
208
Three
25
230 22
460 11
AutoSet C4 Additional
Requirements
Number
of Tables
Circuit
Breaker
(230 V)
1-7 60 A
8-14 100 A
15-24 175 A
NOTE
The electrical requirements are based on use of
one to two gantry heads.
1.2.3. Rod Warning
!
WARNING
Never use a powered tool to turn the bolt and acme rod.
The high RPM generated by using a power tool will cause the
servo motor to generate back current. This back current will cause
the servo drive to fail.
!
WARNING
Only use a wrench to turn the bolt and acme rod
as directed in this manual.
1.2 General Specications
1.2.1. Equipment Specications
Gantry Head Roller Length 15 ft. 4 in.
Gantry Width 18 ft. 3 in.
Gantry Travel Speed 140 in./min.
Table Length 7 ft. 1 in.
Table Width 14 ft. 3 in.
Standard System
Congurations
60, 80, 100 and 120 ft.
Truss Jigging Setups/
Groups
1 to 4 (depending on length)
AutoSet C4 Puck Spacing 1 ft. 9-1/4 in.
Air Requirement
2 CFM per liftout at 100
PSI (when activated, not a
constant draw)
Operating Temperature 32° to 104° F
Footprint