5 AutoSet C4 ™ P R O D U C T M A N U A L EN 1.2.2. Electrical Specications Equipment Voltage Phase Amps Conveyor 110 Single 30 220 15 Gantry 208 Three 25 230 22 460 11 AutoSet C4 Additional Requirements Number of Tables Circuit Breaker (230 V) 1-7 60 A 8-14 100 A 15-24 175 A NOTE The electrical requirements are based on use of one to two gantry heads. 1.2.3. Rod Warning ! WARNING Never use a powered tool to turn the bolt and acme rod. The high RPM generated by using a power tool will cause the servo motor to generate back current. This back current will cause the servo drive to fail. ! WARNING Only use a wrench to turn the bolt and acme rod as directed in this manual. 1.2 General Specications 1.2.1. Equipment Specications Gantry Head Roller Length 15 ft. 4 in. Gantry Width 18 ft. 3 in. Gantry Travel Speed 140 in./min. Table Length 7 ft. 1 in. Table Width 14 ft. 3 in. Standard System Congurations 60, 80, 100 and 120 ft. Truss Jigging Setups/ Groups 1 to 4 (depending on length) AutoSet C4 Puck Spacing 1 ft. 9-1/4 in. Air Requirement 2 CFM per liftout at 100 PSI (when activated, not a constant draw) Operating Temperature 32° to 104° F Footprint