Issue link: http://alpine.uberflip.com/i/221331
HANGER OPTIONS GENERAL NOTES The following options and adjustments factors are applicable only on hangers manufactured by ITW BCG Hardware.. ALLOWABLE LOADS: For multiple options existing on the same hanger, use the adjustment factor that provides for the lowest allowable load. Testing of modified hangers is done using the same basic criteria as is used for testing standard hangers submitted for ICC recognition. In some cases testing of all options available for a specific hanger simultaneous may not be possible. In these cases the option that produces the lowest allowable load is used to determine the adjustment factor required. INSTALLATIONS: 1) The number of fasteners provided for may be more than specified for non-modified hangers. All fasteners must be used to achieve allowable loads 2) For skewed type "A" hangers joist ends must be bevel-cut. For skewed type "B" hangers joist ends may be butt-cut. The supporting member (header) is always assumed fixed during actual installation. Horizontal forces resulting in sloped hanger geometry must be resisted by additional components in the structural system. 3) Sloped seat top flange hangers must be backed. MATERIAL: The gage of steel used in the manufacture of modified hangers may vary from that specified for non-modified hangers depending on the manufacturing process. The number and location of fasteners may vary from non-modified hangers. 4) Non-standard nails specified are provided with product. R410 OSR° BHS/BHSV 50° 45 GH 45° H 67¹⁄₂° 45 HBH 45° 45° 45 HHDTP 50° 45 HTF 45° 45 • • • • 45° HSH • • 45 HDTP • • • SQUARE (BUTT) CUT JOIST REVERSED OR CONCEALED FLANGE • • • RIDGE HANGER • SADDLE HANGER • OFFSET TOP FLANGE • CLOSED TOP FLANGE SLOPED TOP FLANGE 45 OPEN TOP FLANGE SKEWED & SLOPED SEAT 50° BHC BEVEL CUT JOIST D=Seat L=Skewed Top Flange TF=Top Offset Top Sloped Left (20°) Down Left Flange Flange Right Down (20°) Open (20°) (OSR=Offset) (30°) R=Right C=Closed Top Flange (U=Seat Up) Right L=Left X=Special NON-BACKED (Backing reduces possible joist rotation) Standard Stock Model • SLOPED SEAT (MAXIMUM) BH/BHV SKEWED SEAT (MAXIMUM) PRODUCT CODE SLD30° SKL20° TFDL20° TF020° WELDABILITY CODES: Due to the infinite number of variations possible, modified hangers do not have specific ICC recognition. The basic hanger is used with adjustments to allowable load where applicable. X UPLIFT FINISH: Hangers which require welding, to accommodate various options will be painted after fabrication. Non-galvanized hangers may be hot-dipped galvanized after fabrication if specified at time of order; specify HDG. • • • • • • • • • • • • • • • • • • HTP • • • • • • HTPTF • • • LBH 45° 45 • LSS 45° 45 • MBH 45° 45 MBHG 45° MSR/L 45° R/RI 84° 45 • • • • • • • • • • • RA/R/RI 84° 45 • • • • • • • • • • • RH/RHI 84° 45 • • • • • • • • • • RHU 45° 45 • RM/RMI 45° • • • • • • • 45 45 • RSG • • RS/RSI • • • • • • • • • • • • 45 • • • • RSGH 45 • • • • RSH 45 • • • RSL 45 • • • • • • RSO/RSOI 45 • • • • • • • RU/RAU 45° 45 • • S 6¹⁄₂° 45 • • SH 50° 45 • SSR/L 45° TGH/TGHH 45° • • • • • • 45 • • • • • • 47 • •