Issue link: http://alpine.uberflip.com/i/126813
March 2013 For Product Substitutions . . . the ONLY APPROVED EQUAL™ MIN STEM WALL (INCH) REF NO DESIGN LOAD (LBS) MAX (133%) STRAP LENGTH STD MODEL LE (INCH) RIM JOIST MODEL NAIL SCHEDULE HSA SSAD SA EDGE DISTANCE ¹⁄₂" 1¹⁄₂" LE ¹⁄₂" 1¹⁄₂" ¹⁄₂" LE 1¹⁄₂" LE 2000 PSI CONCRETE 2500 PSI CONCRETE 3000 PSI CONCRETE LSSAD8 / LSSAD8RJ LSTHD8 / LSTHD8RJ 6 21⁵⁄₈ 35¹⁄₈ 8 24-16d Sinker 1945 1945 1945 1945 1945 2430 2040 2190 2920 STHD8 / STHD8RJ 6 21⁵⁄₈ 35¹⁄₈ 8 24-16d Sinker 1805 2085 2780 2255 2605 3475 2710 3125 4170 10 28-16d Sinker 2300 2525 3285 2875 3160 4105 3450 3790 4925 14 38-16d Sinker 4075 4365 5820 5095 5455 5820 5820 5820 5820 8 24-16d Sinker 2000 2000 2000 2500 2500 2500 3000 3000 3000 8 24-16d Sinker 2605 2805 4005 3255 3505 5005 3905 4100 5820 3040 3270 4675 3800 3925 5820 4560 4710 5820 4255 4580 5820 5320 5725 5820 5800 5820 5820 SSAD8 / SSAD8RJ SSAD10 / SSAD10RJ SSAD14 / SSAD14RJ LSSAD8 / LSSAD8RJ STHD10 / STHD10RJ 6 STHD14 / STHD14RJ 6 LSTHD8 / LSTHD8RJ SSAD8 / SSAD8RJ 8 STHD8 / STHD8RJ 8 23¹⁄₈ 31⁵⁄₈ 21⁵⁄₈ 21⁵⁄₈ 36⁵⁄₈ 39⁵⁄₈ 35⁵⁄₈ 35¹⁄₈ SSAD10 / SSAD10RJ STHD10 / STHD10RJ 8 23¹⁄₈ 36⁵⁄₈ 10 28-16d Sinker SSAD14 / SSAD14RJ STHD14 / STHD14RJ 8 31⁵⁄₈ 39⁵⁄₈ 14 38-16d Sinker SSAD14RJ uses 30-16d sinkers max. Allowable load @ Le = 5010 @ 133%. Le = Length Embedment HSA3522 or HSA3522-2P For Product Substitutions . . . the ONLY APPROVED EQUAL™ DESIGN LOAD (LBS) MAX (133%) DIMENSIONS (INCHES) REF NO MATERIAL W L MIN STEM WALL (INCH) Le (INCH) 2000 PSI NAIL SCHEDULE 2500 PSI END DISTANCE ¹⁄₂" 8" ¹⁄₂" 8" 12-16d 1160 2320 1450 2320 18-16d 1160 3350 1450 3350 16-16d 1405 3350 1535 3350 24-16d 2110 4865 2300 5030 12-16d 1160 2320 1450 2320 12-16d 1160 2320 1450 2320 16-16d 1405 3350 1755 3350 19-16d 2010 3985 2515 3985 16-16d 2460 3350 2460 3350 24-16d 2460 4865 2460 5030 SINGLE POUR SA2545 HSA3522 PAHD42 HPAHD22 12 ga gal 10 ga gal 2 25³⁄₈ 35 2¹⁄₁₆ 6 8 6 8 6¹⁄₂ 10 SA2545 DOUBLE POUR SA2545 HSA3522 PAHD42 HPAHD22 HSA3522-2P HPAHD22-2P 12 ga gal 10 ga gal 10 ga gal 2 25³⁄₈ 2¹⁄₁₆ 2¹⁄₁₆ SPALLING LOAD REDUCTION 35 39 6 8 6 8 6 8 6¹⁄₂ 10 14 SSAD14RJ Rim Joist Application Installation to Forms SSAD Edge Installation Spalling may occur when strap anchors are bent to a horizontal position and then straightened for installation to framing. This practice may require an adjustment to allowable loads and applies to both single and double pour applications. SSAD14 Two Pour Installation ITW BCG Hardware Corner SSAD Installation on 3-2x studs (for 2 pour, see footnote 4). www.itwbcghardware.com - 800.521.9790 75