Alpine

ITW BCG Hardware Catalog

Issue link: http://alpine.uberflip.com/i/126813

Contents of this Issue

Navigation

Page 52 of 123

March 2013 HANGER OPTIONS GENERAL NOTES The following options and adjustments factors are applicable only on hangers manufactured by ALLOWABLE LOADS: For multiple options existing on the same hanger, use the adjustment factor that provides for the lowest allowable load. Testing of modified hangers is done using the same basic criteria as is used for testing standard hangers submitted for ICC recognition. In some cases testing of all options available for a specific hanger simultaneous may not be possible. In these cases the option that produces the lowest allowable load is used to determine the adjustment factor required. INSTALLATIONS: 1) The number of fasteners provided for may be more than specified for non-modified hangers. All fasteners must be used to achieve allowable loads 2) For skewed type "A" hangers joist ends must be bevel-cut. For skewed type "B" hangers joist ends may be butt-cut. The supporting member (header) is always assumed fixed during actual installation. Horizontal forces resulting in sloped hanger geometry must be resisted by additional components in the structural system. 3) Sloped seat top flange hangers must be backed. MATERIAL: The gage of steel used in the manufacture of modified hangers may vary from that specified for non-modified hangers depending on the manufacturing process. The number and location of fasteners may vary from non-modified hangers. 4) Non-standard nails specified are provided with product. R410 BH/BHV SQUARE (BUTT) CUT JOIST BEVEL CUT JOIST WELDABILITY UPLIFT RIDGE HANGER SADDLE HANGER OFFSET TOP FLANGE CLOSED TOP FLANGE OPEN TOP FLANGE SLOPED TOP FLANGE SLOPED SEAT (MAXIMUM) 45 H NON-BACKED (Backing reduces possible joist rotation) D=Seat L=Skewed Top Flange TF=Top Offset Top Sloped Left (20°) Down Left Flange Flange Right Down (20°) Open (20°) (OSR=Offset) (30°) R=Right C=Closed Top Flange (U=Seat Up) Right L=Left X=Special 45° PRODUCT CODE SKEWED & SLOPED SEAT SKEWED SEAT (MAXIMUM) 50° GH OSR° 45 BHS/BHSV SLD30° SKL20° TFDL20° TF020° Standard Stock Model CODES: Due to the infinite number of variations possible, modified hangers do not have specific ICC recognition. The basic hanger is used with adjustments to allowable load where applicable. 50° X REVERSED OR CONCEALED FLANGE FINISH: Hangers which require welding, to accommodate various options will be painted after fabrication. Non-galvanized hangers may be hot-dipped galvanized after fabrication if specified at time of order; specify HDG. BHC 67¹⁄₂° 45 HBH 45° 45 HDTP 45° 45 HHDTP 45° HSH 50° 45 HTF 45° 45 LBH 45° 45 LSS 45° 45 MBH 45° 45 MBHG 45° HTP HTPTF MSR/L 45° R/RI 84° RA/R/RI 84° 45 RH/RHI 84° 45 RHU 45° 45 RM/RMI 45° 45 45 RS/RSI 45 RSG 45 RSGH 45 RSH 45 RSL 45 RSO/RSOI 45 RU/RAU 45° 45 S 6¹⁄₂° 45 SH 50° 45 SSR/L 45° TGH/TGHH 45° 45 ITW BCG Hardware www.itwbcghardware.com - 800.521.9790 47

Articles in this issue

view archives of Alpine - ITW BCG Hardware Catalog